Item Fef UA9

QSV2 NAGRA TIME VERIER, Nagra speed controller, This unit has a 6 pin Binder/Tuchel plug that plugs into the Nagra 4.2 ACC socket

Your unit will work on a Nagra 4.2 even if it's not a pilot sync recorder. This one will not work on a Nagra IV-S stereo

TO USE WITH A IV-S WITH PILOT SYNC YOU NEED A QSLS SYNCHRONIZER & PILOT LINK PLUG

Record with the pilot link plug in the Nagra pilot socket, then to playback in sync, plug the QSLS into the Nagra pilot socket and the CUE socket and plug the pilot link plug into the QSLS, run the Nagra in playback and switch the QSLS to lock and the QSLS meter with lock in the center, and the Maltese indicators will be white

Plugging the QSV2 into the QSLS will give you a + or - 10% speed change.


If the camera was running at different speeds than the standard 24 or 25 FPS frames per second you could adjust the Nagra to record at the same speed

or if you would like to vary the speed of playback,


To buy this item please telephone: MIKE 01932 241948 OR Email mike.sound@btinternet.com